Independent Validation

Laboratory testing

Emissions from the Nuudelchin stove were measured by the accredited laboratory of the Capital City Air and Environmental Pollution Reduction Department. Every figure below is taken from the test sheet, and each sheet can be opened in full.

Measured against
MNS 5216:2016
NAOBTG laboratory
MNAS · MNS ISO/IEC 17025 · TL 176
2025.08.15Passed

Nuudelchin stove

Fuel type
Improved briquette fuel
Sampled
2025.08.07
Reported
2025.08.15
Sheet no.
TX01/41
PollutantMeasuredLimit
CO1,8159,800
SO₂1861,200
NOₓ90700
TSP98130

mg/nm³ · Measured against: MNS 5216:2016

All pollutants within the permissible maximum

Nuudelchin stove — 2025.08.15View the test sheet
2024.12.13

Nuudelchin stove-2

Fuel type
Improved briquette fuel
Sampled
2024.12.12
Reported
2024.12.13
PollutantMeasuredLimit
CO2,1719,800
SO₂5371,200
NOₓ202700
TSP80130

mg/nm³ · Measured against: MNS 5216:2016

All pollutants within the permissible maximum

Nuudelchin stove-2 — 2024.12.13View the test sheet

Capital City Air and Environmental Pollution Reduction Department · MNAS · MNS ISO/IEC 17025 · TL 176